Fractional CO2 Laser Systems

Fractional CO2 Laser — BG315

Model: BG315

BG315 tabletop 10.6 μm fractional CO2 laser for skin resurfacing; specialist vaginal/intimate laser application requires a confirmed dedicated probe and local authorization.

10.6 μm sealed-off CO2 laser
Adjustable 0–60 W output
12.1-inch foldable LCD touchscreen
7-joint articulated spring arm
Single / continuous / repeated / ultra-pulse modes
Fractional skin resurfacing with a dedicated scanner
Specialist vaginal/intimate laser application: confirm handpiece/configuration

Equipment Details

Machine design & treatment features

Review the equipment layout, treatment approach, included components and configuration details. Any unverified model-specific features are clearly marked for confirmation.

BG315 foldable 12.1-inch display and control screen

Foldable 12.1-inch LCD

A fold-down screen keeps the tabletop footprint compact while giving practitioners a dedicated parameter interface.

Select image to enlarge

BG315 seven-joint laser light-guide arm and fractional applicator

Seven-joint articulated arm

A seven-joint optical arm supports flexible positioning of the fractional treatment head.

Select image to enlarge

Fractional, surface and blend scan shapes

Fractional scanning patterns

Square, triangular, round and hexagonal patterns are pictured, along with rectangle and line options in the fractional interface.

Select image to enlarge

BG315 fractional and surgical operating interfaces

Control interface and operating modes

The pictured interface separates fractional scanning, surgical pulse settings and intimate-application menus. Available menus and compatible treatment heads must be confirmed for the selected configuration; a menu alone does not establish an authorized intended use.

Select image to enlarge

BG315 fractional scanner, separate ultra-pulse head and dedicated vaginal probes; confirm included configuration

Treatment heads and applicators

The image distinguishes the fractional scanner for skin resurfacing, a separate ultra-pulse/surgical handpiece and dedicated vaginal/intimate probes. Vaginal/intimate application is available subject to the selected handpiece/configuration; confirm included accessories before order. Pictured attachments do not establish standard-kit contents or treatment outcomes.

Select image to enlarge

BG315 front and rear parts diagram with ports, key switch and foot switch

Machine body and connections

Front and rear diagrams identify the touch display, key switch, laser port, ventilation and foot-switch connection.

Select image to enlarge

Technical Specifications

Key specifications

Model
BG315
Laser source
Sealed-off CO2 laser
Laser wavelength
10.6 μm
Laser output power
0–60 W, adjustable
Display
12.1-inch foldable LCD touchscreen
Beam delivery
7-joint articulated spring arm
Working modes
Single, continuous, repeated and ultra pulse
Pulse width
0.02–0.99 s
Spot diameter
≤0.4 mm
Divergence angle
4 mrad
Aiming beam
650 nm red diode, ≤5 mW
Cooling system
Air cooling
Surface scan area
2 × 2 mm to 20 × 20 mm
Electrical input
AC 220V ±10%, 50Hz
Input power
≤1000W
Operating temperature
5–40°C
Relative humidity
<80%
Package dimensions
75 × 55 × 33 cm
Gross weight
38 kg

Professional Operation

Session planning & operator guidance

Programme settings are illustrative starting points, not universal treatment prescriptions. Operators should begin gently and adjust to client comfort.

Overview

BG315 is a tabletop multi-application fractional CO2 laser platform combining a 10.6 μm sealed-off source, adjustable 0–60 W output, a 12.1-inch foldable LCD touchscreen and a 7-joint articulated spring arm. Each application uses its corresponding treatment head and settings; confirm the selected configuration before order.

Fractional skin resurfacing uses a dedicated fractional scanner to distribute laser energy across micro-treatment zones separated by surrounding skin. Adjustable scanning coverage and patterns support practitioner-selected protocols for skin texture and the appearance of selected scars and fine lines; outcomes vary with the patient and protocol.

Ultra-pulse/surgical mode uses a separate focused handpiece for specialist cutting or ablation workflows within the confirmed intended use. Single, continuous, repeated and ultra-pulse modes provide different pulse-delivery settings; the surgical handpiece and fractional scanner serve different purposes.

Specialist vaginal/intimate application is available subject to the selected handpiece/configuration; confirm included accessories before order. It requires a dedicated probe, appropriate operator qualifications and confirmation of local regulatory requirements and intended use. A menu or pictured probe does not establish authorization or clinical efficacy for any intimate-health indication.

Applications

Skin & Texture Applications

Skin concerns addressed by fractional resurfacing applications.

Application illustration · not a clinical result

Skin Rejuvenation

For selected fractional resurfacing protocols focused on the appearance of dull or uneven skin texture.

Application illustration · not a clinical result

Acne Scars

May be considered for selected atrophic acne-scar protocols after assessment by a qualified practitioner.

Application illustration · not a clinical result

Fine Lines

For professionally selected resurfacing protocols targeting the appearance of fine lines and photoaging-related texture.

Application illustration · not a clinical result

Pore Refinement

Texture-focused protocols may help improve the appearance of enlarged pores.

Application illustration · not a clinical result

Uneven Texture

For selected skin-resurfacing protocols addressing rough or uneven surface texture.

Application illustration · not a clinical result

Scar Revision

May be considered for selected textural scars where clinically appropriate.

Professional-use equipment. Treatments should be performed by qualified practitioners.

Before quotation

Configuration & accessories

Confirm the exact supplied configuration for BG315.Images show the referenced equipment; the quotation should specify the included accessories and market-specific requirements.

  • Confirm configuration: fractional scanner, supported scanning patterns and compatible tips
  • Confirm configuration: separate ultra-pulse/surgical handpiece and compatible tips; confirm whether included or optional
  • Confirm configuration: dedicated vaginal/intimate probe and intended use; confirm whether included or optional before order
  • Confirm configuration: wavelength-appropriate protective eyewear, protection ratings and quantity supplied
  • Confirm configuration: compatible foot switch and supplied connection accessories
  • Confirm configuration: power plug and site voltage compatibility with AC 220V ±10%, 50Hz
  • Confirm configuration: complete accessory list, quantities, replacement items and care requirements
  • Confirm configuration: operator training, operating documentation and local regulatory documentation available for the intended use
Request a Quote for this equipment

Buyer reviews

What buyers say about Fractional CO2 Laser — BG315

Only moderated, approved reviews are shown. Photos may come from buyers or from our team when a clinic shares permission to publish.

Write a review

Loading reviews…

Buyer Search Keywords

tabletop CO2 laser · BG315 fractional resurfacing

More models in Fractional CO2 Laser Systems