Pigment & Tattoo Laser Systems

Portable Nd:YAG Laser System — P3

Model: P3

P3 Nd:YAG laser system with 532 nm and 1064 nm standard wavelengths, optional 785 nm, a stated 2000 ps (2 ns) pulse width, 1–10 Hz adjustable repetition rate and combined air-and-water cooling.

532 + 1064 nm Standard Wavelengths
Optional 785 nm
2000 ps (2 ns) Pulse Width
Air + Water Cooling

Equipment Details

Machine design & treatment features

Review the equipment layout, treatment approach, included components and configuration details. Any unverified model-specific features are clearly marked for confirmation.

Portable P3 Nd:YAG laser system front view with articulated light-guide arm

Portable Console & Articulated Light-Guide Arm

The desktop unit combines a touchscreen console with an articulated light-guide arm for positioning the laser handpiece. The system uses Nd:YAG laser technology with 532 nm and 1064 nm standard wavelengths.

Select image to enlarge

Close-up of the P3 console showing its 10.1-inch touchscreen

10.1-Inch Operator Touchscreen

The capacitive touchscreen provides controls for wavelength selection, spot size, frequency, energy, lighting count, start/pause and far-infrared adjustment. The startup process includes a self-check and calibration screen.

Select image to enlarge

P3 Nd:YAG laser system and treatment arm

532 nm, 1064 nm & Optional 785 nm

The standard configuration includes 532 nm and 1064 nm wavelengths. A 785 nm wavelength is optional and must be confirmed as part of the ordered configuration.

Select image to enlarge

Rear side of the P3 machine showing connection and ventilation area

Air + Water Cooling with Monitoring

The cooling system combines air and water cooling and provides water-flow and water-temperature monitoring. Fill with purified or medical distilled water before startup and monitor the water circuit during operation.

Select image to enlarge

Close-up of the P3 articulated laser light-guide arm

Optical Arm & Handpiece Care

Keep the light-guide system clean and prevent cold gel from contaminating the optical path. Clean the handpiece probe after use and regularly inspect and clean its lens to help maintain the light output.

Select image to enlarge

P3 rear product view with machine construction details

Water-Circuit Maintenance

Replace the purified water approximately every 15–20 days. Before transport, drain the water, tighten the filling, overflow and drain-port caps, remove the light-guide arm and pack it separately in its dedicated case.

Select image to enlarge

Technical Specifications

Key specifications

Model
P3
Laser type
Nd:YAG
Standard wavelengths
532 nm / 1064 nm
Optional wavelength
785 nm; optional configuration
Pulse duration
2000 ps (2 ns)
Repetition rate
1–10 Hz, adjustable
Spot diameter
2–10 mm
Display
10.1-inch capacitive touchscreen
Cooling system
Air cooling + water cooling
Water monitoring
Water temperature monitoring and water-flow monitoring
Far-infrared adjustment
1–6 levels

Professional Operation

Session planning & operator guidance

Programme settings are illustrative starting points, not universal treatment prescriptions. Operators should begin gently and adjust to client comfort.

Overview

Our P3 is an Nd:YAG laser system with a stated pulse width of 2000 ps (2 ns). This value is equivalent to 2 ns and should not be described as a sub-nanosecond pulse.

The system is listed with 532 nm and 1064 nm standard wavelengths, while 785 nm is available as an optional configuration. Confirm the optional wavelength before quotation.

The 10.1-inch capacitive touchscreen provides controls for spot diameter, wavelength, frequency, energy, lighting count, start/pause and far-infrared adjustment. Water-flow and water-temperature monitoring are also included.

The P3 combines air cooling and water cooling. Fill the system with purified water or medical distilled water before startup, monitor the water circuit during operation and replace the water periodically.

Listed applications include tattoo, eyeliner and lip-liner removal, epidermal and dermal pigmentation, freckles, age spots, sun spots, coffee spots and acquired nevus-like spots of Ota. Suitability and permitted use depend on professional assessment and local requirements.

Applications

Applications & Benefits

Explore the key functions and treatment applications.

01

Tattoo removal, including eyeliner and lip-liner tattoos

02

Epidermal and dermal pigmentation procedures

03

Freckles, age spots and sun spots

04

Coffee spots

05

Acquired nevus-like spots of Ota, subject to professional assessment and local requirements

Professional-use equipment. Treatments should be performed by qualified practitioners.

Before quotation

Configuration & accessories

Confirm the exact supplied configuration for P3.Images show the referenced equipment; the quotation should specify the included accessories and market-specific requirements.

  • Confirm whether the optional 785 nm wavelength is included in the selected unit.
  • Select 110 V or 220 V electrical configuration and confirm the regional plug.
  • Confirm the supplied light-guide arm, wavelength optics, handpiece and accessories.
  • Confirm export-case dimensions and shipping weight for the selected unit.
Request a Quote for this equipment

Buyer reviews

What buyers say about Portable Nd:YAG Laser System — P3

Only moderated, approved reviews are shown. Photos may come from buyers or from our team when a clinic shares permission to publish.

Write a review

Loading reviews…

Buyer Search Keywords

Nd:YAG laser · NdYAG laser · tattoo removal laser · pigmentation laser · portable tattoo laser · 532 nm laser · 1064 nm laser